| The Micro Climate Controller MCC-1 is designed
to perform all the major atmospheric and timed functions required in an automated growth
environment including temperature, humidity, carbon dioxide enrichment, lighting and
irrigation control. The controller incorporates an external coil cooling thermostat , a
dehumidifying humidistat, a 24-hour clock timer, a photo-sensor and a repeat cycle timer.
Heating and humidifying control is provided by triggers for remote high-amperage relays
which enable synchronized equipment management. Automatic override and defeat systems
coordinate controls to consider all possible variables. The MCC-1 is enclosed in a black
anodized, brush finish aluminum housing. An attractive screen-printed front panel with
function indicator lights makes system monitoring and adjustment quick and easy. All
connections are standard 3-prong grounded plugs and receptacles. No hard wiring is
required for basic operations. Low and high voltage relays are available to operate
auxiliary equipment. Every aspect of the growing environment may be addressed by the Micro
Climate Controller (MCC-1). Operates on 110VAC with 15 Amp switching capacity.
The MCC-1 was designed to be used independently or in conjunction with Green Air Products function relays. The MCC-1 will serve independently for systems and equipment requiring 110 VAC of 15 Amps or less. Plug power cord into standard wall outlet and locate controller where good air circulation represents plant zone conditions. Plug exhaust fan into exhaust outlet. Set thermostat and humidistat dials to maximum desired values. Fan will operate when conditions exceed those set points. Function indicator lights will display the condition and outlet status. CO2 equipment can be operated from the CDDS-1 trigger when using the CDMC-2 infrared monitor controller. This outlet provides an exhaust synchronized override feature to delay enrichment during ventilation periods. When timed control is desired plug CO2 equipment into CO2 outlet and set timer mode toggle switch accordingly. Set the sequence timer duration dial for minutes of "On" time and frequency dial for the time between "On" functions. |
|
| Exhaust demand will override CO2 production and timer will reset to cycle immediately following ventilation. CO2 outlet is defeated by a built-in photo sensor to operate only when light is present. If not being used for CO2 enrichment the sequence timer can be used for a variety of other timing duties. Switch the mode toggle to "Cycle Timer" to bypass the exhaust and photoperiod defeat circuits. Timer "On" times as short as 5 sec. can be achieved to operate irrigation pumps or solenoids for all kinds of hydroponic and automatic watering systems. Plug thermostatically controlled heater into HR-1 relay trigger outlet. Exhaust operations will override heating trigger to defeat heaters. Use the HF-1 relay outlet for humidifiers to provide a comfort zone between humidifying and dehumidifying. The 24 hour clock timer is useful for all daily oriented timing operations. The 96 independent 15 min trippers allow any combination of on/off functions repeated each 24 hours. Lighting, fans, pumps and watering are only a few of the tasks this timer can perform. If your combined amperage draw exceeds 15 amp power handling capacity of the controller optional high amperage function relays can be used to provide service to large systems. |
The Master Control
TOTALLY AUTOMATE YOUR SYSTEMS AND EQUIPMENT

Typical Installation Example

Feature Description

FUNCTION OUTLET DESCRIPTIONS
Exhaust Outlet
This outlet receives power when excess heat or humidity need to be ventilated.
Intake and exhaust fans or other venting equipment can be automatically functioned
according to the set-points on the thermostat and humidistat dial face. There is
approximately five points differential between "On" and "Off" cycles
to maintain a consistent air quality.
CDDS-1 Trigger
When using a CO2 monitor to determine and control CO2 producing equipment this outlet provides 24 hr. power which is defeated
during exhaust functions to minimize CO2 loss. Plug CDMC-2 digital
sequencer into this trigger to integrate CO2 management with
atmospheric control.
Timed Outlets
These outlets are operated by the 24 hr. time clock. Use to function almost any
electrical equipment according to time of day settings. This precision synchronous clock
provides 96 independent 15 min. On - Off trippers. Use the HAR-1 relay for high amperage
or voltage equipment.
HR-1 Relay
This feature provides power for heaters or heating relays. A small heater with
built in thermostat can be plugged directly into HR-1 outlet. Larger units must use
heating relay HR-1 to isolate high amperage requirements. Set heating thermostat to
minimum allowable temperature and cooling thermostat to maximum high temperature. The span
between these two settings is the comfort zone. The HR-1 relay outlet will not operate
during exhaust functions.
Cycle Outlet
The cycle outlet utilizes the same internal short cycle timer and operates
simultaneously with the CO2 outlet. When the photo sensor mode
switch is in the cycle timer position the timer is not interrupted by the photo and
exhaust defeat circuits. Both outlets will provide 24 hr. sequence timing for irrigation
systems, pumps, solenoids, transformers, motors, relays and many other equipment devices.
CO2 Outlet
Carbon dioxide enrichment equipment can be precisely timed through this outlet
by the on board cycle timer. This timer will repeat your pre-set "ON" and
"Off" periods continuously whenever the photo sensor detects the presence of
light. The duration of the "On" cycles are from 5 sec. to 30 min. and the
frequency of "On" cycles ( or the "Off" time between them ) is from 7
min. to 8 hrs. The photo sensor mode switch must be in the CO2 timer
position for photo and exhaust function defeat circuits. Reset feature will replenish CO2 immediately after exhaust cycle. Switch mode toggle to "Off"
for manual reset.
HF-1 Relay
This outlet is similar in function to the HR-1 relay outlet except it is for
humidity producing apparatus. Humidifying equipment can not function during dehumidifying
cycles.
IMPORTANT
Make certain the combined amperage draw of all equipment operating through the MCC-1 does not exceed 15 amps. Use function relays to conduct high amperage or alternate voltage currents.
Complete System Control
Function Relay Diagram
| Use Green Air Products function relays in combination with the MCC-1 to operate high voltage or high amperage equipment. The MCC-1 outlets trigger the relay contactor to close which switches power to the auxiliary equipment. This design protects the controller from power overload and provides precise and dependable system management. See detailed descriptions of function relays. |
Click on image to enlarge
Function Relays
Dry Contact Switches
![]() |
The HAR-1 is a power relay that uses high amperage capacity contacts to transfer power to large fans or lighting systems requiring high voltage or amperage service. Use to operate 110 or 240 Volt high draw equipment. 30 Amp switching capacity with 110 Volt trigger. |
![]() |
The HR-1 is a high amperage relay with a built in external coil heating thermostat. Use to supply 110 or 240 Volt power to heating equipment when temperature falls below set point. 30 Amp switching capacity for heavy load requirements. A jack receptacle and internal low voltage dry contacts are used to function gas type heaters. See MCC-1 installation description. |
![]() |
The HF-1 is a high amperage relay with a built in humidifying humidistat. Use to supply 110 or 240 Volt power to humidifying equipment when humidity falls below set point. 30 Amp switching capacity for heavy load requirements. |